Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Ann Otol Rhinol Laryngol ; 133(4): 375-383, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38197379

RESUMO

OBJECTIVE: To describe the phenotypic characteristics of the epiglottis at rest and their impact on vallecular residue. METHODS: Videofluoroscopic studies (VFSS) were pooled from 2 Laryngology practices, and Image J was used to measure epiglottic anatomic features at rest. Studies were rated by the MBSImp and presence of vallecular residue following swallow of thin and puree boluses. A conditional inference tree analysis was performed to isolate which epiglottic parameters were risk factors for presence of vallecular reside followed by logistic regression. RESULTS: The majority of patients had a normal shaped epiglottis, followed by omega shape. The mean angle of the epiglottis from the hyoid was approximately 90°. Only abnormal epiglottic movement was associated with increased risk of residue for thin boluses (OR 35.09, CI 10.93-158.66, P < .001). However, in those with normal epiglottic movement, age >70 years old was associated with increased risk of residue (OR 3.98, CI 1.73-9.23, P = .001). For puree boluses, a normal or omega shaped epiglottis was associated with residue (OR 5.19, CI 2.41-11.51, P < .001), and this relationship was further modulated by increased distance of the epiglottic tip from the posterior pharyngeal wall. No other anatomic features of the resting epiglottis were associated with residue. Comorbidities potentially affecting swallow were infrequent in the cohort and were not associated with residue. CONCLUSION: Abnormal epiglottic movement is associated with aspiration, and in this study we find that abnormal epiglottic movement increases the risk of vallecular residue and that older age is a risk factor for residue. The resting properties of the epiglottis do not appear to be associated with abnormal epiglottic movement or residue.


Assuntos
Transtornos de Deglutição , Epiglote , Humanos , Idoso , Epiglote/diagnóstico por imagem , Transtornos de Deglutição/etiologia , Deglutição , Estudos de Coortes , Faringe/diagnóstico por imagem
2.
J Voice ; 2024 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-38296764

RESUMO

OBJECTIVES/HYPOTHESIS: This study assessed the vocal health of performers returning to full-time performance after the COVID-19 pandemic shutdown and investigated how differences in voice usage, exposure to voice care professionals, and vocal pathology before and during the pandemic contributed to variability in self-perceived and instrumental vocal outcome measures. STUDY DESIGN: This was a prospective, case-control observational study conducted at a single outpatient site. METHODS: Twenty-two patients, 11 cases and 11 controls, were enrolled for the study. All participants were full-time singing professionals prior to the COVID-19 pandemic. Cases were recruited from patients presenting to a tertiary care voice center for vocal or pharyngeal complaints. Controls were healthy volunteers recruited from the general population of professional singers in the surrounding metropolitan area. All participants provided responses to the Voice Handicap Index-10, Evaluation of Ability to Sing Easily, and Laryngopharyngeal Measure of Perceived Sensation validated questionnaires as well as a study survey with questions regarding vocal use and history prior to and during the pandemic. All participants underwent instrumental acoustic and videostroboscopic voice evaluations. RESULTS: Cases had poorer outcome measures overall and were more likely to report their voices were worse at study enrollment when compared to their prepandemic perception (P = 0.027). Cases tended to be older and less likely to have pursued alternative employment during the pandemic that involved increased speaking voice use (27% vs 55%), but these differences were not statistically significant. CONCLUSIONS: There was a variable response among performers to the prolonged hiatus from performing during the COVID-19 pandemic. Those with poorer outcomes tended to be older and may have used their voice less during the pandemic. These findings are consistent with detraining periods in the exercise physiology literature and support the construct of treating vocal performers as vocal athletes.

3.
Laryngoscope ; 134(1): 318-323, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37466294

RESUMO

OBJECTIVE: Simulation may be a valuable tool in training laryngology office procedures on unsedated patients. However, no studies have examined whether existing awake procedure simulators improve trainee performance in laryngology. Our objective was to evaluate the transfer validity of a previously published 3D-printed laryngeal simulator in improving percutaneous injection laryngoplasty (PIL) competency compared with conventional educational materials with a single-blinded randomized controlled trial. METHODS: Otolaryngology residents with fewer than 10 PIL procedures in their case logs were recruited. A pretraining survey was administered to participants to evaluate baseline procedure-specific knowledge and confidence. The participants underwent block randomization by postgraduate year to receive conventional educational materials either with or without additional training with a 3D-printed laryngeal simulator. Participants performed PIL on an anatomically distinct laryngeal model via trans-thyrohyoid and trans-cricothyroid approaches. Endoscopic and external performance recordings were de-identified and evaluated by two blinded laryngologists using an objective structured assessment of technical skill scale and PIL-specific checklist. RESULTS: Twenty residents completed testing. Baseline characteristics demonstrate no significant differences in confidence level or PIL experience between groups. Senior residents receiving simulator training had significantly better respect for tissue during the trans-thyrohyoid approach compared with control (p < 0.0005). There were no significant differences in performance for junior residents. CONCLUSIONS: In this first transfer validity study of a simulator for office awake procedure in laryngology, we found that a previously described low-cost, high-fidelity 3D-printed PIL simulator improved performance of PIL amongst senior otolaryngology residents, suggesting this accessible model may be a valuable educational adjunct for advanced trainees to practice PIL. LEVEL OF EVIDENCE: NA Laryngoscope, 134:318-323, 2024.


Assuntos
Internato e Residência , Laringoplastia , Laringe , Otolaringologia , Treinamento por Simulação , Humanos , Competência Clínica , Endoscopia , Laringe/cirurgia , Otolaringologia/educação , Impressão Tridimensional , Treinamento por Simulação/métodos
4.
Laryngoscope ; 133(12): 3512-3519, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37485725

RESUMO

OBJECTIVE: To compare the effectiveness of disinfection protocols utilizing a ultraviolet (UV) Smart D60 light system with Impelux™ technology with a standard Cidex ortho-phthalaldehyde (OPA) disinfection protocol for cleaning flexible fiberoptic laryngoscopes (FFLs). METHODS: Two hundred FFLs were tested for bacterial contamination after routine use, and another 200 FFLs were tested after disinfection with one of four methods: enzymatic detergent plus Cidex OPA (standard), enzymatic detergent plus UV Smart D60, microfiber cloth plus UV Smart D60, and nonsterile wipe plus UV Smart D60. Pre- and post-disinfection microbial burden levels and positive culture rates were compared using Kruskal-Wallis ANOVA and Fisher's two-sided exact, respectively. RESULTS: After routine use, approximately 56% (112/200) of FFLs were contaminated, with an average contamination level of 9,973.7 ± 70,136.3 CFU/mL. The standard reprocessing method showed no positive cultures. The enzymatic plus UV, microfiber plus UV, and nonsterile wipe plus UV methods yielded contamination rates of 4% (2/50), 6% (3/50), and 12% (6/50), respectively, with no significant differences among the treatment groups (p > 0.05). The pre-disinfection microbial burden levels decreased significantly after each disinfection technique (p < 0.001). The average microbial burden recovered after enzymatic plus UV, microfiber plus UV, and nonsterile wipe plus UV were 0.40 CFU/mL ± 2, 0.60 CFU/mL ± 2.4, and 12.2 CFU/mL ± 69.5, respectively, with no significant difference among the treatment groups (p > 0.05). Micrococcus species (53.8%) were most frequently isolated, and no high-concern organisms were recovered. CONCLUSION: Disinfection protocols utilizing UV Smart D60 were as effective as the standard chemical disinfection protocol using Cidex OPA. LEVEL OF EVIDENCE: NA Laryngoscope, 133:3512-3519, 2023.


Assuntos
Laringoscópios , Humanos , Laringoscópios/microbiologia , Glutaral , Detergentes , Desinfecção/métodos , o-Ftalaldeído , Contaminação de Equipamentos/prevenção & controle
5.
Respir Physiol Neurobiol ; 312: 104037, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36842729

RESUMO

3D models of airway lumens were created from CT scans of 19 patients with laryngotracheal stenosis. Computational fluid dynamics (CFD) simulations were completed for each, and results were compared to measured peak inspiratory flow rate, grade of lumen constriction, and measures of airway geometry. Results demonstrate flow resistance and shear stress correlate with degree of lumen constriction and absolute cross-sectional area as well as flow rate. Flow recirculation depends on airway constriction but does not vary with flow rate. Resistance and wall shear stress did not correlate well with functional measures. Flow recirculation did differ between subjects with higher functional measures and subjects with lower functional measures. This analysis provides mathematical models to predict airway resistance, wall shear stress, and flow reversal according lumen constriction and inspiratory flow rate. It suggests aerodynamic factors such as flow recirculation play a role in differences in functional performance between patients with similar airway measures.


Assuntos
Hidrodinâmica , Laringoestenose , Humanos , Constrição Patológica , Imageamento Tridimensional , Laringoestenose/diagnóstico por imagem , Pulmão
6.
Laryngoscope ; 133(10): 2654-2664, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-36715102

RESUMO

OBJECTIVE: To compare outcomes between two standard-of-care anesthesia regimens for operative laryngoscopy: general anesthesia with a neuromuscular blocking agent (NMBA) versus remifentanil and propofol (non-NMBA). METHODS: This was a prospective, single-blinded, randomized controlled trial at a tertiary care center. Patients were randomized to either anesthesia using rocuronium (NMBA) or with remifentanil/propofol infusion alone (non-NMBA). Intraoperative impressions, anesthesia data, and post-operative patient surveys were collected. RESULTS: Sixty-one patients who underwent suspension laryngoscopy from 2020 to 2022 were included (25 female, 36 male, ranging 20-81 years). Thirty patients were enrolled in the NMBA arm and 31 patients in the non-NMBA arm. Heart rate and mean arterial pressure were higher in the NMBA (p < 0.01). Patients in the non-NMBA group were more likely to require vasopressors (p = 0.04, RR = 3.08 [0.86-11.05]). Surgeons were more frequently satisfied with conditions in the NMBA group (86.7%) compared to the non-NMBA group (58.1%, p < 0.01). Procedures were more likely to be paused due to movement in the non-NMBA group (45.1%) compared to the NMBA group (16.6%, p < 0.03, RR = 2.26 [1.02-4.99]). Patients in the non-NMBA group were more likely to endorse myalgia the week after surgery (44%) compared to the NMBA group (8.3%, p < 0.01) and reported higher average pain levels on a 0-10 pain scale (3.7) compared to the paralysis group (2.0). CONCLUSIONS: Anesthesia with rocuronium was associated with better intraoperative conditions and postoperative pain compared to anesthesia with remifentanil/propofol. Remifentanil/propofol were associated with lower blood pressure and suppression of laryngoscopy-associated tachycardia. LEVEL OF EVIDENCE: 2 Laryngoscope, 133:2654-2664, 2023.


Assuntos
Fármacos Neuromusculares não Despolarizantes , Propofol , Humanos , Masculino , Feminino , Rocurônio , Remifentanil , Anestésicos Intravenosos , Androstanóis , Laringoscopia/efeitos adversos , Laringoscopia/métodos , Estudos Prospectivos , Piperidinas , Anestesia Geral , Dor
7.
IEEE Trans Biomed Eng ; 69(12): 3678-3688, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35594214

RESUMO

OBJECTIVE: Objective evaluation of physiological responses using non-invasive methods for the assessment of vocal performance and voice disorders has attracted great interest. This paper, for the first time, aims to implement and evaluate perilaryngeal-cranial functional muscle networks. The study investigates the variations in topographical characteristics of the network and the corresponding ability to differentiate vocal tasks. METHOD: Twelve surface electromyography (sEMG) signals were collected bilaterally from six perilaryngeal and cranial muscles. Data were collected from eight subjects (four females) without a known history of voice disorders. The proposed muscle network is composed of pairwise coherence between sEMG recordings. The network metrics include (a) network degree and (b) weighted clustering coefficient (WCC). RESULTS: The varied phonation tasks showed the median degree, and WCC of the muscle network ascend monotonically, with a high effect size ( |rrb| âˆ¼ 0.5). Pitch glide, singing, and speech tasks were significantly distinguishable using degree and WCC ( |rrb| âˆ¼ 0.8). Also, pitch glide had the highest degree and WCC among all tasks (degree , WCC ). In comparison, classic spectrotemporal measures showed far less effectiveness (max |rrb|=0.12) in differentiating the vocal tasks. CONCLUSION: Perilaryngeal-cranial functional muscle network was proposed in this paper. The study showed that the functional muscle network could robustly differentiate the vocal tasks while the classic assessment of muscle activation fails to differentiate. SIGNIFICANCE: For the first time, we demonstrate the power of a perilaryngeal-cranial muscle network as a neurophysiological window to vocal performance. In addition, the study also discovers tasks with the highest network involvement, which may be utilized in the future to monitor voice disorders and rehabilitation.


Assuntos
Distúrbios da Voz , Voz , Feminino , Humanos , Eletromiografia , Voz/fisiologia , Fonação/fisiologia , Distúrbios da Voz/diagnóstico , Músculos
8.
Laryngoscope ; 131(10): 2199-2203, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33152152

RESUMO

OBJECTIVES/HYPOTHESIS: We sought to identify changes that occur in spirometric values between surgical interventions in patients with recurrent laryngotracheal stenosis and assess the utility of tracking those changes in predicting the need to return to surgery. METHODS: This is a retrospective, case-control study of laryngotracheal stenosis. Charts from a 10 year period were reviewed, and 80 patients were identified with recurrent laryngotracheal stenosis and serial spirometry. Recorded forced expiratory volume in 1 second (FEV1 ), forced inspiratory volume in 1 second (FIV1 ), peak expiratory flow (PEF), and peak inspiratory flow (PIF), and body mass index (BMI) were tabulated. Calculations were then performed to determine deviations in spirometric measurements from maximums. Comparing the patients who required intervention to those who did not, we used a regression analysis to generate a decision tree based on factors with the strongest predictive power. We then calculated receiver operating characteristic (ROC) curves for all calculated variables. RESULTS: Deviations in PEF, PIF, and FIV1 from each patient's maximums had strong predictive power in determining return to surgery. PIF was the only fixed measurement found to have a statistically significant role in predicting return to surgery. BMI did not play a role. CONCLUSION: For each patient, the deviation from their overall spirometric maximums had the statistically strongest predictive power in determining need to return to surgery. This suggests the importance of the trends in spirometric measures for each individual, and implies these trends have greater import than fixed measures alone. LEVEL OF EVIDENCE: 4 Laryngoscope, 131:2199-2203, 2021.


Assuntos
Laringoestenose/cirurgia , Espirometria/estatística & dados numéricos , Estenose Traqueal/cirurgia , Idoso , Estudos de Casos e Controles , Humanos , Laringoestenose/diagnóstico , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Recidiva , Estudos Retrospectivos , Medição de Risco/métodos , Medição de Risco/estatística & dados numéricos , Estenose Traqueal/diagnóstico
9.
J Biomech ; 104: 109752, 2020 05 07.
Artigo em Inglês | MEDLINE | ID: mdl-32224051

RESUMO

Tracheal stenosis is a health condition in which local narrowing of the upper trachea can cause breathing difficulties and increased incidence of infection, among other symptoms. Occurring most commonly due to intubation of infants, tracheal stenosis often requires corrective surgery. It is challenging to determine the most effective surgical strategy for a given patient as current clinical methods used to assess tracheal stenosis are simplistic and subjective, and are not rigorously based on aerodynamic considerations. This paper summarizes a non-invasive approach based on computational fluid dynamics (CFD) and medical imaging to establish relationships between trachea anatomy and inspiration performance. Though patient-specific CFD analysis has gained recent popularity, an objective of this study is to computationally formulate dimensionless analytical correlations between anatomy and performance that are applicable to any member of a class of patients and that can be interpreted within the context of the Myer-Cotton stenotic airway classification system. These correlations can provide aerodynamics-based insight for the development of more robust stenosis evaluation methods and may allow for time-efficient assessment of corrective surgical strategies.


Assuntos
Estenose Traqueal , Criança , Constrição Patológica , Humanos , Hidrodinâmica , Incidência , Lactente , Traqueia/diagnóstico por imagem , Estenose Traqueal/diagnóstico por imagem , Estenose Traqueal/etiologia
10.
Acta Otolaryngol ; 136(6): 592-7, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26852777

RESUMO

Conclusion Measurement of the posterior airway space (PAS) using modified barium swallow (MBS) appears to correlate well with CT imaging. This data suggests MBS may be a low-cost alternative imaging modality to assess obstructive sleep apnea patients. Objectives Obstructive sleep apnea research has focused on imaging modalities that supplement polysomnography in evaluation of potential sites of airway obstruction. While several techniques have been used to assess the PAS, many incur significant costs and risks to the patient. This study proposes use of MBS as a simple modality to measure PAS. Advantages include its simplicity, lower radiation, and dynamic tongue base visualization, which may help predict surgical outcomes. It is hypothesized that cephalometric measurements obtained using MBS will correlate well with CT. Methods Thirty-six adult patients who underwent both CT imaging and MBS for head and neck cancer were included. Cephalometric measurements of the PAS were obtained using each imaging modality. Statistical analysis focused on correlating measurements taken using CT and MBS. Results The average PAS measurements were 12.53 ± 1.81 mm and 12.80 ± 1.75 mm by MBS and CT imaging, respectively. In comparing the two modalities, Pearson correlation between CT and MBS measurements revealed significant positive correlations between r = 0.769 and 0.937.


Assuntos
Sulfato de Bário , Apneia Obstrutiva do Sono/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...